Optimass 9500 Inductively Coupled Plasma Time of Flight Mass Spectrometer

All ion information within the range of 1-260amu can be obtained simultaneously. Full-spectrum direct-reading ICP-MS. It can achieve instantaneous analysis and is very convenient to be combined with injection techniques such as laser ablation, electrothermal evaporation, and HPLC.

Optimass 9500 Inductively Coupled Plasma Time of Flight Mass Spectrometer

At the same time, the ion information in the range of 1-260amu is obtained - ICP-MS with full spectrum direct reading!

It can realize instantaneous analysis and is easy to be combined with laser ablation, electrothermal evaporation, HPLC and other sampling technologies.

With high-quality resolution ability (238U high-quality end > 2000);

The right-angle acceleration design reduces the velocity divergence in the direction of ion drift (the initial velocity is 0), further improving the resolution ability of the instrument;

Three-stage cone four-stage vacuum design makes the instrument have higher stability and measurement precision.

High quality selectivity, the ion whitener Smartgate effectively eliminates interfering ions (such as Ar + and matrix interfering ions), the spectrum is cleaner, and the lifespan of the detector is effectively extended;

Powerful anti-interference ability of Ar ions and matrix ions, easier to operate than reaction cell technology, stronger anti-interference ability;

Adopt high linearity detector with wide dynamic range.

Automatic optimization of instrument parameters.

With semi-quantitative and traceable semi-quantitative functions, it can automatically store all mass information for future quantitative analysis.

With fingerprint function, it is very convenient to compare spectra.

Key Features

Look More

Optimass 9500 Inductively Coupled Plasma Time of Flight Mass Spectrometer

At the same time, the ion information in the range of 1-260amu is obtained - ICP-MS with full spectrum direct reading!

It can realize instantaneous analysis and is easy to be combined with laser ablation, electrothermal evaporation, HPLC and other sampling technologies.

With high-quality resolution ability (238U high-quality end > 2000);

The right-angle acceleration design reduces the velocity divergence in the direction of ion drift (the initial velocity is 0), further improving the resolution ability of the instrument;

Three-stage cone four-stage vacuum design makes the instrument have higher stability and measurement precision.

High quality selectivity, the ion whitener Smartgate effectively eliminates interfering ions (such as Ar + and matrix interfering ions), the spectrum is cleaner, and the lifespan of the detector is effectively extended;

Powerful anti-interference ability of Ar ions and matrix ions, easier to operate than reaction cell technology, stronger anti-interference ability;

Adopt high linearity detector with wide dynamic range.

Automatic optimization of instrument parameters.

With semi-quantitative and traceable semi-quantitative functions, it can automatically store all mass information for future quantitative analysis.

With fingerprint function, it is very convenient to compare spectra.